Verified Electrical & Mechanical Specifications
Product Overview & Dielectric Architecture
MKP-X2 is an across-the-line EMI safety film capacitor built for continuous connection between live and neutral in AC mains circuits. Its metallized polypropylene dielectric delivers low loss and stable capacitance, while the flame-retardant plastic case with epoxy potting meets UL94 V-0. Rated at 250V, 275V, or 310V AC (50/60Hz), it covers 0.1µF to 3.3µF with ±5% (J) or ±10% (K) tolerance, making it a practical choice for global appliance and power-supply platforms.
Engineers specify MKP-X2 where conducted EMI must be attenuated without compromising safety. The 100 V/µs maximum dV/dt supports the pulse currents typical of switching supplies, and the self-healing metallized film clears local dielectric faults rather than failing short. Popular values such as 0.1µF, 0.15µF, 0.22µF, and 0.33µF simplify BOM standardization across induction cookers, LED drivers, smart meters, and capacitive dropper supplies.
Electrical Behavior & Compliance Standards
Electrically, MKP-X2 behaves as a low-loss AC capacitor: dissipation factor stays at or below 0.001 at 1kHz for values up to 1µF, and at or below 0.002 above 1µF. That low tan δ keeps self-heating modest under continuous 50/60Hz line voltage and the high-frequency ripple riding on it. The metallized polypropylene construction also provides self-healing; a localized breakdown vaporizes the thin metal electrode around the fault, isolating it and preserving capacitance.
Safety margins are defined by the dielectric withstand ratings: 4.3×UR (VDC) for 10 seconds terminal-to-terminal, and 2000V AC minimum for 60 seconds terminal-to-case. The 40/105/21 climatic category (VDE/ENEC/CQC) and the 40/110/56/B rating cover demanding appliance and outdoor-meter environments. MKP-X2 is designed and tested to IEC 60384-14, UL60384-14, and GB/T 14472-1998, with UL94 V-0 flame retardance on the encapsulated case.
Circuit Selection & Typical Applications
Sizing MKP-X2 starts with the line voltage and the required EMI attenuation. Choose 250V, 275V, or 310V AC according to the mains and the safety margin your end product requires, then pick capacitance from 0.1µF to 3.3µF to hit the target insertion loss without excessive leakage current. The 100 V/µs dV/dt ceiling sets the maximum pulse current the part should see in service.
- Confirm continuous AC voltage and expected transients against the 250/275/310V AC ratings.
- Select ±5% (J) tolerance for filter networks needing tighter cutoff; ±10% (K) suits general EMI suppression.
- Verify the 100 V/µs dV/dt limit against measured or simulated pulse currents in the dropper or filter stage.
- Check the 40/105/21 or 40/110/56/B climatic category against the enclosure's internal temperature rise.
- Match lead spacing and case size to the PCB footprint early to avoid late layout changes.
- For capacitive dropper circuits, confirm the series resistor and fuse coordination with the selected capacitance.
- Across-the-Line EMI/RFI Interference Suppression
- Home Appliance Control PCBs & Induction Cookers
- LED Driver Modules & Smart Meters
- Capacitive Power Supply Dropper Circuits
OEM Manufacturing & Quality Screening
SMILER produces MKP-X2 at its Foshan, Guangdong facility, where nine automated lines and a dedicated QA/QC team support roughly 300,000 units per day. Every capacitor passes 100% electrical screening, including AC/DC empowerment and DC withstand voltage testing, backed by an in-house laboratory for flame, leakage, and dimensional checks. Finished-product qualification is maintained at or above 99.93%.
For OEM programs, prototyping can be completed in as little as 5 days, and average mass-production delivery runs about 15 days. Custom capacitance, voltage rating, case dimensions, lead configuration, and private-label marking are available, so appliance and meter makers can standardize MKP-X2 across multiple PCB designs without requalifying a new suppression platform.
Explore related industrial applications, browse our engineering selection guides, or request a MKP-X2 datasheet and sample quote.
MKP-X2 Frequently Asked Questions
What is the difference between the 40/105/21 and 40/110/56/B climatic categories for MKP-X2?
The 40/105/21 rating is verified under VDE, ENEC, and CQC schemes and covers -40°C to +105°C with 21 days of damp heat testing. The 40/110/56/B rating extends the upper limit to +110°C with 56 days of damp heat, suiting harsher enclosure environments. Select based on the measured internal temperature and humidity of your end product.
Can MKP-X2 replace a generic X2 capacitor in an existing LED driver design?
MKP-X2 meets IEC 60384-14, UL60384-14, and GB/T 14472-1998 and offers 250V, 275V, or 310V AC ratings with 0.1µF to 3.3µF values. Check that the capacitance, ±5% or ±10% tolerance, lead spacing, and 100 V/µs dV/dt limit match the original part. Confirm the 4.3×UR and 2000V AC withstand margins against your circuit's transient profile before substitution.
What lead time and customization options does SMILER offer for MKP-X2 orders?
SMILER quotes a shortest sample lead time of 5 days and an average mass-production lead time of 15 days from its Foshan plant. Custom capacitance, voltage rating, case size, lead or terminal style, and OEM marking are supported. Every unit receives 100% electrical screening, and finished-product qualification is maintained at or above 99.93%.
Related Capacitor Series
Need Datasheets or Custom OEM Film Capacitors?
Send your capacitance, voltage rating, and mechanical drawing. Our 9-member engineering team replies within 24 hours with 5-day prototyping availability.